Schneider Acti9 xC60 MCB 3 Pole 10kA – Trusted Three Phase Circuit Protection
The Schneider Electric Acti9 xC60 3 pole MCB is a high-quality three-phase miniature circuit breaker that protects your wiring and equipment from overload and short-circuit damage. With a 10kA breaking capacity – much higher than the 4.5kA or 6kA of common breakers – it safely interrupts heavy fault currents found in apartment buildings, factories and commercial distribution boards.
PB SHOP BD supplies the original Schneider TP MCB in Bangladesh in ratings 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A and 63A – perfect for three-phase motors, central AC units, lifts, water pumps and industrial machines.

Key Features
- 100% original Schneider Electric Acti9 – world-leading quality and safety.
- 3 pole (TP) – disconnects all three phases together for safe isolation.
- 10kA breaking capacity – reliable protection even near transformers and big DBs.
- C-curve tripping – handles motor starting current without nuisance tripping.
- Fast & accurate trip – thermal element for overload, magnetic coil for short circuit.
- Clear ON/OFF indicator and lockable toggle for safe maintenance.
- Finger-safe IP20 terminals with strong clamping for long-term reliability.
- Standard 35mm DIN-rail fit for all modern distribution boxes.
Applications
- Three-phase distribution boards (TPN DB) in buildings and apartments
- Motors, pumps, compressors and lifts
- Central air conditioners and VRF outdoor units
- Factory machines, garments and workshops
- Commercial kitchens, hospitals and offices
- Solar inverter AC output (3-phase)
How to Choose the Right MCB Rating
Select the MCB rating just above your load current and within the cable capacity. Typical three-phase 415V guide: 2–4A for control circuits and small motors (≤1.5kW), 6–10A ≈ 2–5kW, 16A ≈ 7.5kW, 20–25A ≈ 10–12kW, 32A ≈ 15kW, 40A ≈ 20kW, 63A ≈ 30kW. For cable: 2.5mm² up to 20A, 4mm² up to 25–32A, 6mm² up to 40A, 16mm² for 63A (approximate – follow local wiring rules).
Why Buy from PB SHOP BD?
- Genuine Schneider Electric MCB
- Best Schneider MCB price in Bangladesh
- 1 year warranty
- Fast delivery across Bangladesh with cash on delivery
FAQ
Q: What is the difference between 6kA and 10kA MCB?
A: kA is the maximum fault current the breaker can safely break. A 10kA MCB is safer for large buildings and locations close to the transformer.
Q: Can I use a 3 pole MCB for a single-phase load?
A: It is designed for three-phase circuits. For single-phase use a 1P or 2P MCB.
Q: What does C-curve mean?
A: C-curve MCBs trip magnetically at 5–10 times rated current, suitable for motors, ACs and general loads.
Note: Installation should be done by a qualified electrician.